This product has been discontinued.

VM600 rack controller and communications interface card.

The VM600 CPUM and IOCN modular CPU card and input/output card is a rack controller and communications interface card pair that acts as a system controller and data communications gateway for a VM600 rack-based machinery protection system (MPS) and/or condition monitoring system (CMS) from Meggitt’s Vibro-Meter® product line.

Note: Different versions of CPUx/IOCx rack controller and communications interface card pair are available, as follows:

  • The CPUM/IOCN is the original version with a front-panel display and support for Modbus RTU/TCP or PROFINET (PNR 200-595-VVV-VVV).
  • The CPUR/IOCR is a version with rack controller redundancy and support for Modbus RTU/TCP (PNR 600-007-VVV-VVV).
  • The CPUR2/IOCR2 is a version with mathematical processing of fieldbus data and support for Modbus TCP and PROFIBUS DP (PNR 600-026-000-VVV).

Features

  • VM600 CPUM/IOCN rack controller and communications interface card pair with support for Modbus RTU/TCP or PROFINET, and a front-panel display
  • “One-Shot” configuration management of protection cards (MPC4 and AMC8) in a VM600 rack using an Ethernet or RS-232 serial connection to a computer running the VM600 MPSx software
  • Front-panel display for visualisation of monitored outputs and alarm limits from protection cards
  • Common alarm reset (AR) for protection cards and VM600 MPS rack (CPUM) security
  • VM600 system event and measurement event logs available via the VM600 MPSx software

Additional information

Monitoring system (application)

Machinery protection, condition monitoring, combustion monitoring

VM600 system function

Common

VM600 system component

Processing card

VM600 component function

Rack controller and communications interface

VM600 component and rack compatibility

ABE040, ABE042

VM600 communications interfaces

Modbus RTU/TCP or PROFINET

VM600 rack alarm reset (AR)

Yes

VM600 MPS rack (CPUx) security

Yes

VM600 event logs

System event and measurement event logs (up to 10000)

VM600 output relays

0