VM600 CPUR rack controller and communications interface card
These cards are discontinued with some spares available.
– VM600: no replacement.
– VM600Mk2: replaced by CPUMMk2 + IOCNMk2 with redundancy (via firmware upgrade) available 2024.
- VM600 CPUR/IOCR rack controller and communications interface card pair with support for Modbus RTU/TCP and card pair redundancy
- “One-Shot” configuration management of protection cards (MPC4 and AMC8) in a VM600 rack using an Ethernet connection to a computer running the VM600 MPSx and VibroSight® software
- Rack controller and communications redundancy with two CPUR/IOCR card pairs: Master (active) and Inactive (redundant)
- Five output relays to signal system statuses and alarms
- VM600 system event and measurement event logs available via VibroSight® software
Description
These cards are discontinued with some spares available.
– VM600: no replacement.
– VM600Mk2: replaced by CPUMMk2 + IOCNMk2 with redundancy (via firmware upgrade) available 2024.
VM600 rack controller and communications interface card.
The VM600 CPUR and IOCR rack controller and communications interface card pair is a central processing unit (CPU) card pair that acts as a system controller and data communications gateway for a VM600 rack-based machinery protection system (MPS) and/or condition monitoring system (CMS) from Meggitt’s Vibro-Meter® product line.
Note: Different versions of CPUx/IOCx rack controller and communications interface card pair are available, as follows:
- The CPUM/IOCN is the original version with a front-panel display and support for Modbus RTU/TCP or PROFINET (PNR 200-595-VVV-VVV).
- The CPUR/IOCR is a version with rack controller redundancy and support for Modbus RTU/TCP (PNR 600-007-VVV-VVV).
- The CPUR2/IOCR2 is a version with mathematical processing of fieldbus data and support for Modbus TCP and PROFIBUS DP (PNR 600-026-000-VVV).
Features
- VM600 CPUR/IOCR rack controller and communications interface card pair with support for Modbus RTU/TCP and card pair redundancy
- “One-Shot” configuration management of protection cards (MPC4 and AMC8) in a VM600 rack using an Ethernet connection to a computer running the VM600 MPSx and VibroSight® software
- Rack controller and communications redundancy with two CPUR/IOCR card pairs: Master (active) and Inactive (redundant)
- Five output relays to signal system statuses and alarms
- VM600 system event and measurement event logs available via VibroSight® software
Additional information
Monitoring system (application) | Machinery protection, condition monitoring, combustion monitoring |
---|---|
VM600 system function | Common |
VM600 system component | Processing card |
VM600 component function | Rack controller and communications interface |
VM600 component and rack compatibility | ABE040, ABE042 |
VM600 communications interfaces | Modbus RTU/TCP |
VM600 rack alarm reset (AR) | No |
VM600 MPS rack (CPUx) security | No |
VM600 event logs | System event and measurement event logs (up to 1000) |
VM600 output relays | 5 |
The following downloads are available for this product: