LS121 air-gap sensor
- Designed for the contactless measurement of the air-gap between rotor and stator in hydroelectric generators, and large alternators and motors
- 20 to 60 mm linear measurement range (15 to 65 mm)
- −15 to 125 °C operating temperature
- Withstands magnetic fields up to 1.5 tesla
- Integral cable length of 5 or 10 m
Description
20 to 60 mm range, −15 to 125 °C, 1.5 tesla.
The LS121 air-gap sensor is a high-quality, high-reliability air-gap sensor for use with an ILS731 signal conditioner, which provides voltage outputs and a current output.
The LS121 is designed and built for long-term use in extreme environments characterised by high temperatures and/or high-strength magnetic fields.
Features
- Designed for the contactless measurement of the air-gap between rotor and stator in hydroelectric generators, and large alternators and motors
- 20 to 60 mm linear measurement range (15 to 65 mm)
- −15 to 125 °C operating temperature
- Withstands magnetic fields up to 1.5 tesla
- Integral cable length of 5 or 10 m
Additional information
Linear measurement range | 0.79 to 2.4 in | 20 to 60 mm |
---|---|
Operating temperature range | 5 to 257 °F | −15 to 125 °C |
Magnetic field | Up to 1.5 Tesla |
Sensor dimensions | 14 x 2.4 x 0.19 in | 345 x 60 x 4.8 mm |
Integrated cable length | 16.4 or 32.8 ft | 5.0 or 10.0 m |
The following downloads are available for this product:
Related products
-
- LS120 air-gap sensor
- Designed for the contactless measurement of the air-gap between rotor and stator in hydroelectric generators, and large alternators and motors
- 5 to 30 mm linear measurement range (1.875 to 33.125 mm)
- −15 to 125 °C operating temperature
- Withstands magnetic fields up to 1.5 tesla
- Integral cable length of 5 or 10 m