Designed for the long-term measurement of vibration over wide temperature ranges in extreme environments, such as gas turbines or cryogenic applications

  • Operating temperature: −54 to 500 °C, −253 (20 K) to 500 °C for cryogenic version
  • Frequency response: 0.5 to 6000 Hz
  • Available as a sensor only (no integral cable) or with an integral mineral-insulated (MI) with a double braid
  • Certified for use in potentially explosive atmospheres
Compare

Description

The CA134 piezoelectric accelerometer is a vibration sensor with a piezoelectric sensing element that provides a charge output. Accordingly, an external charge amplifier (IPC707 signal conditioner), is required to convert this charge-based signal into a current or a voltage signal.

The CA134 is designed and built for long-term use in extreme environments characterised by high temperatures and/or hazardous areas (potentially explosive atmospheres).

Features

  • Sensitivity: 10 pC/g
  • Operating temperature: −54 to 500 °C, −253 (20 K) to 500 °C for cryogenic version
  • Frequency response: 0.5 to 6000 Hz
  • Measurement range: up to 500 g
  • Available as a sensor only (no integral cable) or with an integral mineral-insulated (MI) with a double braid
  • Certified for use in potentially explosive atmospheres

Additional information

Output type

Charge (2-wire)

Sensitivity

10 pC/g | 1.02 pC / m/s2

Operating temperature range

−65 to 932 °F | −54 to 500 °C

Frequency response

Up to 6000 Hz

Sensitivity tolerance

±5%

Dynamic measurement range

0.001 to 500 g | 0.00981 to 4905 m/s2

Linearity

±1%

Transverse sensitivity

<5%

Resonant frequency

>14 kHz

Base strain sensitivity

<7E−4 g/µε

Hazardous area certifications

Ex ia, Ex ib, Ex nA

The following downloads are available for this product:

Related products

  • CA202 piezoelectric accelerometer
    • CA202 piezoelectric accelerometer
    • CA202 piezoelectric accelerometer
    • Designed for the long-term measurement of vibration in extreme environments, such as heavy-duty gas turbines and steam turbine

      • Operating temperature: −55 to 260 °C
      • Frequency response: 0.5 to 6000 Hz
      • Available with an integral soft-line cable with a flexible stainless steel hose
      • Certified for use in potentially explosive atmospheres
    Compare
  • CA901 piezoelectric accelerometer
    • CA901 piezoelectric accelerometer
    • CA901 piezoelectric accelerometer
    • Designed for the long-term measurement of vibration in extreme environments, such as gas turbines and nuclear applications

      • Operating temperature: −196 to 700 °C
      • Frequency response: 3 to 3700 Hz
      • Available with an integral mineral-insulated (MI) cable
      • Certified for use in potentially explosive atmospheres
    Compare
  • CA280 piezoelectric accelerometer
    • CA280 piezoelectric accelerometer
    • CA280 piezoelectric accelerometer
    • Designed for the long-term measurement of vibration in extreme environments, such as gas turbines, gearboxes and compressors

      • Operating temperature: −60 to 260 °C
      • Frequency response: 0.5 to 6000 Hz
      • Available as a sensor only (no integral cable) or with an integral soft-line cable with a flexible stainless steel hose
      • Certified for use in potentially explosive atmospheres
    Compare