PA150 probe mounting adaptor with proximity measurement chain

  • Removable probe housing and probe adaptor rod containing a complete proximity measurement chain (TQ912 and IQS900)
  • 2 or 4 mm measurement range (Ø8.2 mm sensor)
  • Sealed die-cast aluminium housing and stainless steel adaptor rod, with choice of mounting orientation
  • Easier probe installation and gap adjustment with adaptor rod lengths from 50 to 800 mm (mounting position adjustable to ±10 mm)
  • Certified for use in potentially explosive atmospheres
Compare

Description

Complete probe mounting adaptor with proximity measurement chain (TQ912 and IQS900).

High-quality, high-reliability removable probe housing and probe adaptor rod containing a complete proximity measurement chain that consists of a TQ912 proximity sensor and a IQS900 signal conditioner, which provides either a voltage output or a current output (2 mm range: 8 mV/µm or 2.5 µA/µm, 4 mm range: 4 mV/µm or 1.25 µA/µm).

The PA150 is designed and built for long-term use in harsh environments characterised by industrial temperatures and/or hazardous areas (potentially explosive atmospheres).

Features

  • Removable probe housing and probe adaptor rod containing a complete proximity measurement chain (TQ912 and IQS900)
  • 2 or 4 mm measurement range (Ø8.2 mm sensor)
  • Sealed die-cast aluminium housing and stainless steel adaptor rod, with choice of mounting orientation
  • Easier probe installation and gap adjustment with adaptor rod lengths from 50 to 800 mm (mounting position adjustable to ±10 mm)
  • Certified for use in potentially explosive atmospheres

Additional information

Output type

Current (2-wire) or voltage (3-wire)

Type of probe mounting adaptor

Removable probe housing and probe adaptor rod

Mounting position adjustment

±0.39 in | ±10 mm

Probe housing material

Aluminium alloy

Probe housing gasket material

Nitrile rubber (NBR)

Probe adaptor rod material

Stainless steel 1.4301

Probe adaptor assembly material

Stainless steel 1.4305

Mounting orientation for probe housing

Longitudinal or perpendicular

Configurable adaptor length for probe

Yes

Temperature range

−31 to 185 °F | −35 to 85 °C

Protection rating

IP65

Hazardous area certifications

Ex e

The following downloads are available for this product: