IQS900 signal conditioner
- Signal conditioning for TQ proximity sensors.
- Shaft relative vibration and gap/position measurement for machinery protection and/or advanced condition monitoring.
- Very wide frequency range (DC to 20000 Hz), with configurable sensitivity and measurement range.
- Current output for long-distance signal transmission or voltage output for medium-distance signal transmission.
- Certified for use in potentially explosive atmospheres (Ex) and/or safety-related applications (SIL).
- Fully compliant with API 670 5th edition.
Description
The IQS900 signal conditioner is designed for operation with vibro-meter TQ proximity sensors, that is, non-contact proximity sensors / measurement chains based on the eddy-current principle.
Note: The IQS900 is compatible with different TQ9xx (and TQ4xx sensors) and replaces all previous versions of the IQS45x signal conditioner (PNR 244-45x-000-xxx).
The IQS900 signal conditioner provides a dynamic output signal – current (−15.5 to −20.5 mA) or voltage (−1.6 V to −17.6 V) – suitable for advanced condition monitoring applications that require spectral analysis, for example, machinery analytics and diagnostics. In comparison, the IQS910 signal conditioner provides a slowly-varying output signal (4 to 20 mA current-loop) suitable for machinery protection and/or basic condition monitoring applications based on cost-effective trending of overall levels.
The IQS900 is a configurable and versatile device that generates, converts and processes (high-frequency modulator/demodulator) signals from a TQ proximity sensor into a current or voltage output signal suitable for transmission to the monitoring system. For example, it is factory-configurable for sensitivity and measurement range (transfer function), system length, and optional diagnostic circuitry (with variants defined by ordering option code).
The IQS900 is designed and built for long-term use, and is available in standard versions and in Ex versions certified for use in potentially explosive atmospheres (hazardous areas). Similarly, it is also available with or without diagnostics: versions with diagnostics automatically and remotely indicate the health/status of the measurement chain so you always know when measurements can be trusted. The diagnostics (SIL 2 “by design”) bring enhanced reliability and significant risk reduction, making the IQS900 suitable for use in safety-related applications (functional safety contexts).
Features
- Signal conditioning for TQ proximity sensors.
- Shaft relative vibration and gap/position measurement for machinery protection and/or advanced condition monitoring.
- Very wide frequency range (DC to 20000 Hz), with configurable sensitivity and measurement range.
- Current output for signal transmission over long distances or voltage output for signal transmission over medium distances.
- Certified for use in potentially explosive atmospheres (hazardous areas).
- Suitable for use in functional safety contexts: SIL 2 in accordance with IEC 61508 and Cat 1 PL c in accordance with ISO 13849.
- Fully compliant with API 670 5th edition.
- “Raw” output and “Test” input signals for in-situ test support.
The following downloads are available for this product:
- TQ902/TQ912, EA902 and IQS900 proximity measurement chain data sheet
- TQ922/TQ932, EA902 and IQS900 proximity measurement chain data sheet
- TQ942, EA902 and IQS900 proximity measurement chain data sheet
- TQ401, EA401 and IQS900 proximity measurement chain data sheet
- TQ402/TQ412, EA402 and IQS900 proximity measurement chain data sheet
- TQ403, EA403 and IQS900 proximity measurement chain data sheet
- LCIE 21 ATEX 1004 X Ex certificate (Europe) – TQ9xx, IQS9xx
- LCIE 21 ATEX 3002 X Ex certificate (Europe) – IQS9xx
- IECEx LCIE 21.0005X Ex certificate (International) – TQ9xx, IQS9xx
- IECEx LCIE 21.0006X Ex certificate (International) – IQS9xx
- cCSAus 80084516 Ex certificate (North America) – TQ9xx, IQS9xx
- CML 21 UKEX 4549 X Ex certificate (United Kingdom) – TQ9xx, IQS9xx
- CML 21 UKEX 2548 X Ex certificate (United Kingdom) – IQS9xx
- KGS 21-GA4BO-0355X Ex certificate (South Korea) – IQS9xx
- KGS 21-GA4BO-0353X Ex certificate (South Korea) – IQS9xx
- KGS 21-GA4BO-0352X Ex certificate (South Korea) – IQS9xx
- EAЭC RU C-CH.AД07.B.03744/21 Ex certificate (Russian Federation) – TQ9xx, IQS9xx
- 204-900-000V011 product drawing [ LOGIN required ]
- Proximity measurement chains using TQ9xx proximity sensors installation manual [ LOGIN required ]
Related products
-
- IQS910 signal conditioner
- Signal conditioning for TQ proximity sensors.
- Position (gap) or vibration (shaft relative) measurement for machinery protection and/or basic condition monitoring.
- Wide frequency range (DC to 15000 Hz), with configurable measurement type (position or vibration), sensitivity and measurement range.
- Position measurement or vibration measurement with “peak-meter” vibration processing.
- Industry-standard 4 to 20 mA current-loop output.
- Certified for use in potentially explosive atmospheres (Ex) and/or safety-related applications (SIL).
-
- EA902 extension cable
- Very high-quality, reliable extension cable for TQ9x2 proximity measurement chains
- 70 Ω coaxial cable with FEP insulation (Ø3.6 mm)
- 1-core, with shield
- Self-locking miniature coaxial connector (female) to self-locking miniature coaxial connector (male)
- Versions certified for use in potentially explosive atmospheres
- Conforms to API 670 5th edition
-
- TQ912 proximity sensor
- Designed for the contactless measurement of relative vibration and axial displacement in turbines, compressors, pumps and fans
- 2 or 4 mm measurement range (Ø8.2 mm sensor)
- −40 to 180 °C operating temperature, IP68 protection rating
- 0.5, 1.0, 1.5, 2.0 or 5.0 m integral coaxial cable.
- Versions certified for use in potentially explosive atmospheres
- Conforms to API 670 5th edition
-
- TQ902 proximity sensor
- Designed for the contactless measurement of relative vibration and axial displacement in turbines, compressors, pumps and fans
- 2 or 4 mm measurement range (Ø8.2 mm sensor)
- −40 to 180 °C operating temperature, IP68 protection rating
- 0.5, 1.0, 1.5, 2.0 or 5.0 m integral coaxial cable
- Versions certified for use in potentially explosive atmospheres
- Conforms to API 670 5th edition