VM600 IOCN input/output card for CPUM card

These cards are discontinued with spares no longer available, please see below for an updated alternative.
– VM600: replaced by CPUR2 and IOCR2.
– VM600Mk2: replaced by CPUMMk2 + IOCNMk2.

  • Input/output (interface) card for CPUM card
  • One primary Ethernet connector (8P8C (RJ45)) for communication with the VM600 MPSx software and/or Modbus TCP and/or PROFINET communications
  • One secondary Ethernet connector (8P8C (RJ45)) for redundant Modbus TCP communications
  • One primary serial connector (6P6C (RJ11/RJ25)) for communication with the VM600 MPSx software via a direct connection
  • Two pairs of serial connectors (6P6C (RJ11/RJ25)) that can be used to configure multi-drop RS-485 networks of VM600 racks

This product is no longer available for purchase. Please use the enquiry button only if you require support, otherwise please select the product below.

Compare

Description

These cards are discontinued with spares no longer available.

Input/output card for VM600 CPUM modular CPU card.

The VM600 CPUM and IOCN modular CPU card and input/output card is a rack controller and communications interface card pair that acts as a system controller and data communications gateway for a VM600 rack-based machinery protection system (MPS) and/or condition monitoring system (CMS) from Meggitt’s Vibro-Meter® product line.

Features

  • Input/output (interface) card for CPUM card
  • One primary Ethernet connector (8P8C (RJ45)) for communication with the VM600 MPSx software and/or Modbus TCP and/or PROFINET communications
  • One secondary Ethernet connector (8P8C (RJ45)) for redundant Modbus TCP communications
  • One primary serial connector (6P6C (RJ11/RJ25)) for communication with the VM600 MPSx software via a direct connection
  • Two pairs of serial connectors (6P6C (RJ11/RJ25)) that can be used to configure multi-drop RS-485 networks of VM600 racks

Additional information

Monitoring system (application)

Machinery protection, condition monitoring, combustion monitoring

VM600 system function

Common

VM600 system component

Interface (input/output) card

VM600 component function

Rack controller and communications interface

VM600 component and rack compatibility

ABE040, ABE042

VM600 communications interfaces

Modbus RTU/TCP or PROFINET

VM600 rack alarm reset (AR)

Yes

VM600 MPS rack (CPUx) security

Yes

VM600 event logs

System event and measurement event logs (up to 10000)

VM600 output relays

0