Skip to content
VM600 AMC8 analog monitoring card
8 temperature or process monitoring channels
1 processed output per channel and 1 processed output per multi-channel (4 per AMC8)
Highly configurable card supports temperature monitoring using thermocouples and/or RTDs, and process monitoring using current and/or voltage inputs
Highly integrated card pair (with IOC8T) includes DC outputs, relays and serial communications interfaces
Designed for operation with the VM600 MPSx software
Compare
VM600 CPUM modular CPU card
VM600 CPUM/IOCN rack controller and communications interface card pair with support for Modbus RTU/TCP or PROFINET, and a front-panel display
“One-Shot” configuration management of protection cards (MPC4 and AMC8) in a VM600 rack using an Ethernet or RS-232 serial connection to a computer running the VM600 MPSx software
Front-panel display for visualisation of monitored outputs and alarm limits from protection cards
Common alarm reset (AR) for protection cards and VM600 MPS rack (CPUM) security
VM600 system event and measurement event logs available via the VM600 MPSx software
Compare
VM600 CPUR rack controller and communications interface card
VM600 CPUR/IOCR rack controller and communications interface card pair with support for Modbus RTU/TCP and card pair redundancy
“One-Shot” configuration management of protection cards (MPC4 and AMC8) in a VM600 rack using an Ethernet connection to a computer running the VM600 MPSx and VibroSight® software
Rack controller and communications redundancy with two CPUR/IOCR card pairs: Master (active) and Inactive (redundant)
Five output relays to signal system statuses and alarms
VM600 system event and measurement event logs available via VibroSight® software
Compare
VM600 CPUR2 rack controller and communications interface card
VM600 CPUR2/IOCR2 rack controller and communications interface card pair with support for Modbus TCP and PROFIBUS DP
“One-Shot” configuration management of protection cards (MPC4) in a VM600 rack using an Ethernet connection to a computer running the VM600 MPSx and VibroSight® software
Mathematical processing of data to be shared via fieldbus and card pair status (health) information via fieldbus
Common alarm reset (AR) for protection cards and VM600 MPS rack (CPUR2) security with a removable key
Two output relays to signal system statuses and alarms
Compare
VM600 IOC4T input/output card for MPC4 cards
Input/output (interface) card for an MPC4 or MPC4SIL card – supports 4 dynamic channels and 2 tachometer channels
Differential signal input with sensor power supply output per dynamic channel and per tachometer channel
Differential buffered (raw) transducer output per dynamic channel
DC output configurable as current-based signal (4 to 20 mA) or voltage-based signal (0 to 10 V) per dynamic channel
4 configurable relays with two contacts available per relay, and alarm reset (AR), danger bypass (DB) and trip multiply (TM) control inputs
Compare
VM600 IOC8T input/output card for AMC8 card
Input/output (interface) card for an AMC8 card – supports 8 temperature or process monitoring channels
Configurable signal input with current source output per monitoring channel
DC output configurable as current-based signal (4 to 20 mA) or voltage-based signal (0 to 10 V) per monitoring channel
4 configurable relays with three contacts available per relay, and alarm reset (AR) and danger bypass (DB) control inputs
Compare
VM600 IOCN input/output card for CPUM card
Input/output (interface) card for CPUM card
One primary Ethernet connector (8P8C (RJ45)) for communication with the VM600 MPSx software and/or Modbus TCP and/or PROFINET communications
One secondary Ethernet connector (8P8C (RJ45)) for redundant Modbus TCP communications
One primary serial connector (6P6C (RJ11/RJ25)) for communication with the VM600 MPSx software via a direct connection
Two pairs of serial connectors (6P6C (RJ11/RJ25)) that can be used to configure multi-drop RS-485 networks of VM600 racks
Compare
Compare
Compare
VM600 IRC4 intelligent relay card
Additional relays, driven by equations with up to 86 inputs from MPC4 and/or AMC8 cards for when more complex logic such as 2oo3 voting is required
8 relays configurable as 8 SPDT or 4 DPDT
Fully software configurable using the IRC4 Configurator software
Relays configurable as normally energised (NE) or normally de-energised (NDE), with configurable delays
All relay contacts are available on the screw-terminal connectors
Compare
VM600 machinery protection system software (MPS1 and MPS2)
MPS1 for configuration and MPS2 for configuration and trending
Live data (MPS1 and MPS2) and historical data (MPS2 only)
Graphical user interface
Runs on Windows® Server 2003, Windows NT, Windows 2000, Windows XP, Windows Vista, Windows 7 and Windows 10 operating systems
Available in 3 languages (English, French, German)
Compare
VM600 MPC4 machinery protection card
4 dynamic channels and 2 tachometer channels
2 processed outputs per dynamic channel and 1 processed output per dual-channel (2 per MPC4), 1 processed output per tacho channel
Highly configurable card supports all measurements required by machinery protection applications, such as relative and/or absolute vibration
Highly integrated card pair (with IOC4T) includes sensor power supplies, buffered outputs, DC outputs, relays and serial communications interfaces
Designed for operation with the VM600 MPSx software
Compare
VM600 MPC4SIL machinery protection card
4 dynamic channels
2 processed outputs per dynamic channel and 1 processed output per dual-channel (2 per MPC4)
Highly configurable card supports a subset of SIL 1 approved measurements for machinery protection, including relative and/or absolute vibration
Highly integrated card pair (with IOC4T) includes sensor power supplies, buffered outputs, DC outputs, relays and serial communications interfaces
Designed for operation with the VM600 MPSx software
Compare
VM600 RLC16 relay card
Additional relays, driven by MPC4 and/or AMC8 card signals for when the 4 relays on the IOC4T and IOC8T cards are not enough
16 SPDT relays
Hardware configurable
Relays configurable as normally energised (NE) or normally de-energised (NDE)
All relay contacts are available on the screw-terminal connectors
Compare
VM600 XIO16T input/output module for XMx16 modules
Input/output (interface) module for the XMV16 and XMC16 modules – supporting 16 dynamic channels and 4 tachometer channels
Differential signal input per dynamic channel and tachometer channel
Designed for operation with the VibroSight® software: one Ethernet connector (8P8C (RJ45)) for communication with VibroSight
Compare
VM600 XMC16 condition monitoring module for combustion
16 dynamic channels and 4 tachometer channels
Up to 20 processed outputs per dynamic channel and per dual-channel (12 per XMC16)
Simultaneous data acquisition on all channels with asynchronous (fixed frequency) or synchronous (order tracked) sampling
24-bit data acquisition, high SNR data processing, with a high-resolution FFT up to 6400 lines every 500 ms
Designed for operation with the VibroSight® software
Compare
VM600 XMV16 condition monitoring module for vibration
16 dynamic channels and 4 tachometer channels
Up to 20 processed outputs per dynamic channel and per dual-channel (12 per XMV16)
Simultaneous data acquisition on all channels with asynchronous (fixed frequency) or synchronous (order tracked) sampling
24-bit data acquisition, high SNR data processing, with a high-resolution FFT up to 6400 lines every 500 ms
Designed for operation with the VibroSight® software
Compare